{"product_id":"dover-urine-drainage-bags","title":"Dover Urine Drainage Bags, 1000 to 4000 mL","description":"\u003ch1\u003eCardinal Health Dover Urine Bedside Drainage Bag\u003c\/h1\u003e\n\n\u003cp\u003e\u003cstrong\u003eSKUs: 3057 | 3512 | 3512V | 6206 | 6208 | 6261 | 6308LL | 8206 | 550235\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e1000mL–4000mL Capacity  |  MONO-FLO Anti-Reflux (Select Models)  |  SplashGuard II Drain Spout (Select Models)  |  40\"\/45\"\/48\" Tubing  |  Sampling Port Options  |  Universal Hanging Device  |  HCPCS A4357  |  Prescription Required  |  FSA\/HSA Eligible\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e⚠ California Prop 65 Warning:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information visit \u003ca href=\"https:\/\/www.p65warnings.ca.gov\" target=\"_blank\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe Cardinal Health Dover line of urine bedside drainage bags (formerly Covidien) covers the full range of institutional and home care bedside drainage needs — from a 1000mL pediatric bag to a 4000mL high-capacity adult bag, with multiple anti-reflux configurations, drain spout designs, tubing lengths, and sampling port options. A universal hanging device fits all standard bed frames and drainage bag holders. Easy-to-read graduated markings for urine output monitoring. Prescription required. FSA\/HSA eligible.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eOrder by Part Number\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSKU\u003c\/th\u003e\n      \u003cth\u003eCapacity\u003c\/th\u003e\n      \u003cth\u003eTubing\u003c\/th\u003e\n      \u003cth\u003eAnti-Reflux\u003c\/th\u003e\n      \u003cth\u003eDrain Spout\u003c\/th\u003e\n      \u003cth\u003eSampling\u003c\/th\u003e\n      \u003cth\u003eQuantity\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e3057\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e3512\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e40\"\u003c\/td\u003e\n      \u003ctd\u003eChamber\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e3512V\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e40\"\u003c\/td\u003e\n      \u003ctd\u003eChamber\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eCase\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e6206\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eBarrier\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e6208\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eValve\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e6261\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e6308LL\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eValve\u003c\/td\u003e\n      \u003ctd\u003eSplashGuard II\u003c\/td\u003e\n      \u003ctd\u003eLuer Lock Port\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e8206\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eChamber\u003c\/td\u003e\n      \u003ctd\u003eStandard\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach | Case\/20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e550235\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2000 mL\u003c\/td\u003e\n      \u003ctd\u003e48\"\u003c\/td\u003e\n      \u003ctd\u003eValve\u003c\/td\u003e\n      \u003ctd\u003eSplashGuard II\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n      \u003ctd\u003eEach\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSelect the SKU that matches your prescribed anti-reflux and drain spout configuration. Questions? \u003cstrong\u003e\u003ca href=\"tel:18662180902\"\u003e1-866-218-0902\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMultiple capacities — 1000mL pediatric, 2000mL standard adult, 2350mL large adult, 4000mL high-capacity adult; match capacity to patient output and facility protocols\u003c\/li\u003e\n  \u003cli\u003eMONO-FLO anti-reflux device — Cardinal Health's proprietary anti-reflux mechanism on select models; a one-way fluid control device preventing urine from flowing back toward the catheter\u003c\/li\u003e\n  \u003cli\u003eAnti-reflux chamber — dome-shaped internal chamber design on select models; structurally prevents backflow without a mechanical valve component\u003c\/li\u003e\n  \u003cli\u003eAnti-reflux valve — mechanical one-way valve on select models\u003c\/li\u003e\n  \u003cli\u003eNo anti-reflux (SKUs 3057, 6261) — for facilities and protocols that manage backflow through patient positioning alone\u003c\/li\u003e\n  \u003cli\u003eSplashGuard II drain spout — one-hand drain operation; protective spout design reduces urine splash during bag emptying; on SKUs 6308LL and 550235\u003c\/li\u003e\n  \u003cli\u003eLarge vertical drip chamber — clear chamber in-line on the tubing; allows continuous visual monitoring of urine flow rate without reading the bag graduations\u003c\/li\u003e\n  \u003cli\u003eLuer lock sampling port (SKU 6308LL) — allows closed urine specimen collection without disconnecting the drainage system\u003c\/li\u003e\n  \u003cli\u003eClosed system aspirating port (select models) — needle-free urine sampling port on the drainage tubing\u003c\/li\u003e\n  \u003cli\u003eUniversal hanging device — fits all standard bed frames, IV poles, and drainage bag holders; included with each bag\u003c\/li\u003e\n  \u003cli\u003eEasy-to-read graduated markings — for urine output measurement and documentation\u003c\/li\u003e\n  \u003cli\u003e11\/32-inch tubing diameter — supports adequate urine flow rate\u003c\/li\u003e\n  \u003cli\u003eTubing length options: 40\" (3512, 3512V, 8206), 45\" (pediatric models), 48\" (all other models)\u003c\/li\u003e\n  \u003cli\u003eClear bag material — visual inspection of urine color, clarity, and character\u003c\/li\u003e\n  \u003cli\u003eHCPCS code A4357 — facilitates insurance billing for covered patients\u003c\/li\u003e\n  \u003cli\u003ePrescription required | FSA\/HSA eligible\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch2\u003eClinical FAQs\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is the MONO-FLO anti-reflux device and how does it differ from a chamber or valve?\u003c\/h3\u003e\n\u003cp\u003eMONO-FLO is Cardinal Health's branded anti-reflux mechanism, used across the Dover drainage bag line. Unlike a simple one-way valve (a mechanical flapper or ball that blocks reverse flow) or a dome-shaped anti-reflux chamber (which traps the fluid column geometrically), the MONO-FLO device uses a proprietary fluid-flow control design that channels urine in only one direction — from catheter toward the bag — while preventing any return flow regardless of patient position or bag movement. For prescribers and facilities specifying anti-reflux drainage bags, the presence or absence of the MONO-FLO or chamber on a specific Dover SKU affects which bag is appropriate for the infection-control protocol in use. Bags without anti-reflux (SKUs 3057 and 6261) are appropriate when facility protocols manage backflow risk through strict patient positioning only.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the SplashGuard II drain spout and why does it matter during bag emptying?\u003c\/h3\u003e\n\u003cp\u003eThe SplashGuard II is a Cardinal Health drain spout design with a protective geometry around the drainage outlet that reduces splashing of urine when the bag is emptied. In a standard drain spout, opening the outlet allows urine to flow freely — if the stream hits the inside of a graduated collection container at an angle, back-splash can contaminate the surrounding area and the hands of the person emptying the bag. The SplashGuard II's one-hand operation mechanism also allows the drainage outlet to be opened and directed without requiring two-hand manipulation. For caregivers managing multiple patients with drainage bags, or for patients with limited hand function who empty their own bags, the SplashGuard II spout reduces contamination risk and simplifies the emptying step. It is available on SKUs 6308LL and 550235.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the large vertical drip chamber and what does it allow clinical staff to see?\u003c\/h3\u003e\n\u003cp\u003eThe vertical drip chamber is a clear, rigid section in the drainage tubing positioned between the catheter connection and the main bag. As urine drains from the bladder through the catheter, it passes through this chamber before entering the bag. The chamber's vertical orientation and clear construction allow the caregiver to see the drip rate — how many drops of urine are passing through per minute — without removing or reading the main bag. This provides continuous visual confirmation that urine is flowing freely and the catheter is not obstructed. If the drip rate slows or stops, this is visible immediately in the chamber rather than requiring an inspection of the bag's total volume. For post-operative and critical care settings where catheter patency must be confirmed at a glance, the drip chamber provides an early visual indicator of potential obstruction.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I select the right Dover SKU for my patient?\u003c\/h3\u003e\n\u003cp\u003eFour variables determine the correct SKU: capacity, tubing length, anti-reflux design, and drain spout\/sampling port features. For capacity: match to expected output and emptying interval — 2000mL for most standard adult use; 4000mL (SKU 6261) for high-output patients, high-dose diuretic therapy, or when extended intervals between emptying are needed. For tubing length: 40\" (SKUs 3512\/3512V\/8206) for closer bedside placement; 48\" (most models) for greater reach to the foot of the bed or for ambulating patients. For anti-reflux: select chamber, MONO-FLO, or valve per facility infection-control protocol; use no-anti-reflux models (3057, 6261) only when indicated. For drain spout: SplashGuard II (6308LL, 550235) for cleaner single-hand emptying; standard spout for routine use. The Luer lock sampling port on 6308LL is the right choice when regular urine specimen collection is part of the care plan.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is HCPCS code A4357 and why does it appear on this product?\u003c\/h3\u003e\n\u003cp\u003eHCPCS (Healthcare Common Procedure Coding System) codes are standardized codes used by Medicare, Medicaid, and most private insurers to identify and reimburse specific medical supplies and devices. Code A4357 is the designated code for urinary drainage bags — it identifies this product category to insurance payers for reimbursement processing. For institutional purchasers, home health agencies, and patients submitting claims for drainage bag coverage, the A4357 code is required on the claim form. Coverage under Medicare Part B for drainage bags is typically linked to an indwelling catheter that is medically necessary — the clinical documentation supporting catheter necessity also supports drainage bag reimbursement. Patients ordering for personal home use should confirm coverage and authorization with their insurance plan.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestions about SKU selection, MONO-FLO vs. standard anti-reflux, or institutional case pricing?\u003c\/strong\u003e Call our product specialists: \u003cstrong\u003e\u003ca href=\"tel:18662180902\"\u003e1-866-218-0902\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Covidien","offers":[{"title":"Default Title","offer_id":55234612658545,"sku":"3512","price":4.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/6122\/9681\/files\/ken-3512_2.webp?v=1780426419","url":"https:\/\/www.medicaldepartmentstore.com\/products\/dover-urine-drainage-bags","provider":"Medical Department Store","version":"1.0","type":"link"}