Joerns DermaFloat APL Alternating Pressure Low Air Loss Therapy Mattress System
/
Joerns DermaFloat APL Alternating Pressure Low Air Loss Therapy Mattress System
Call 866-218-0902 to speak with a mattress specialist.
Clinical-grade dual therapy system — alternating pressure improves circulation and relieves pressure points while integrated low air loss airflow manages heat and moisture for advanced wound care support.
The DermaFloat APL is a high-performance mattress system built for patients at moderate to high risk of pressure injuries. It combines alternating pressure therapy with integrated low air loss airflow, addressing both pressure redistribution and microclimate management in a single, clinical-grade system.
Its A/B air cell alternating design continuously shifts pressure points across the body, promoting circulation and reducing tissue stress, while the low air loss system delivers consistent airflow beneath the patient to control heat and moisture buildup.
With approximately 20 individual air cells and high airflow output, the DermaFloat APL provides reliable, consistent support across extended periods of use — making it a strong choice for long-term care and clinical environments where performance cannot be compromised.
Who Is This Mattress Best For?
- Patients at moderate to high risk for pressure injuries
- Patients with existing wounds requiring advanced skin protection
- Individuals on extended bed rest with limited mobility
- Care settings where heat and moisture control is a clinical priority
- Hospitals, long-term care facilities, and advanced home care environments
Quick Summary
- Alternating pressure + low air loss dual therapy
- A/B air cell alternating system for continuous pressure redistribution
- High airflow output — up to ~40 LPM — for effective moisture management
- ~20 individual air cells for full-surface pressure support
- Alternating and static operating modes
- Fluid-resistant, low-shear, antimicrobial cover
Why Choose the DermaFloat APL?
The DermaFloat APL sits above standard dual therapy systems in both airflow output and pressure redistribution consistency. Its A/B cell design means that while one set of cells deflates to relieve pressure, the alternating cells remain inflated to maintain full body support — eliminating the unsupported gaps that less sophisticated systems can create.
The high-output low air loss function delivers airflow at a volume that meaningfully reduces skin moisture and temperature — particularly important for patients with existing wounds or those prone to skin maceration.
If you need an alternating pressure mattress with clinical-level low air loss performance and proven wound care support, the DermaFloat APL is a widely trusted solution across hospital and long-term care settings.
Key Specifications
- Therapy Type: Alternating Pressure + Low Air Loss
- Air Cell Design: A/B alternating system
- Air Cells: ~20 individual cells
- Airflow Output: Up to ~40 LPM
- Operating Modes: Alternating and Static
- Cover: Fluid-resistant, low-shear, antimicrobial
- Recommended Use: Hospital, long-term care, advanced home care
Compare Advanced Alternating Pressure Mattress Systems
- Protekt Aire 9000BL — Low Air Loss & Alternating Pressure Mattress System
- Protekt Aire 5000DX — Low Air Loss & Alternating Pressure Mattress System
- Invacare microAIR MA800 — Alternating Pressure Low Air Loss Mattress System
View all Alternating Pressure & Low Air Loss Mattress Systems →
Browse APP Pads, Overlays & Gel Mattresses →
Further Reading
Want to understand how alternating pressure compares to low air loss and lateral rotation systems — and how to choose the right level of care for your patient?
Product Specifications / Dimensions
| Mattress Dimensions | 80"L x 36"W x 8"D |
| Mattress Weight | 22 lbs / 4.5 Kg |
| Mattress Maximum Weight Capacity | 350 lbs / 159 Kg |
| CairRails Safety Feature | Yes |
| CPR Quick Deflation | Yes |
| Comfort Control Settings | Yes |
| Number of Comfort Control Settings | 8 |
| Operational Modes | Yes |
| Number of Operational Modes | 3 |
| Cycle Time Intervals (Minutes) | 5 / 10 / 15 |
| Control Unit Dimensions | 12.25"H x 7.5"W x 5.5"D |
| Control Unit Weight | 10 lbs / 4.5 Kg |
| Electrical Specifications | 120V AC / 60 Hz / 0.6A |
| Operating Conditions Ambient Temperature | 50 - 104 Degrees (Fahrenheit) / 10 - 40 Degrees (Celsius) |
| Operating Conditions Relative Humidity | 30% - 75% (Non-Condensing) |
| Storage and Shipping Conditions Ambient Temperature | 50 - 104 Degrees (Fahrenheit) / 10 - 40 Degrees (Celsius) |
| Storage and Shipping Conditions Relative Humidity | 10% - 100% |
| Control Unit Agency Approvals | UL Classified Medical Equipment UL 60601-1 Can/CSA C22.2 No. 601.1 |
Product Specifications / Dimensions
| Mattress Dimensions | 80"L x 36"W x 8"D |
| Mattress Weight | 22 lbs / 4.5 Kg |
| Mattress Maximum Weight Capacity | 350 lbs / 159 Kg |
| CairRails Safety Feature | Yes |
| CPR Quick Deflation | Yes |
| Comfort Control Settings | Yes |
| Number of Comfort Control Settings | 8 |
| Operational Modes | Yes |
| Number of Operational Modes | 3 |
| Cycle Time Intervals (Minutes) | 5 / 10 / 15 |
| Control Unit Dimensions | 12.25"H x 7.5"W x 5.5"D |
| Control Unit Weight | 10 lbs / 4.5 Kg |
| Electrical Specifications | 120V AC / 60 Hz / 0.6A |
| Operating Conditions Ambient Temperature | 50 - 104 Degrees (Fahrenheit) / 10 - 40 Degrees (Celsius) |
| Operating Conditions Relative Humidity | 30% - 75% (Non-Condensing) |
| Storage and Shipping Conditions Ambient Temperature | 50 - 104 Degrees (Fahrenheit) / 10 - 40 Degrees (Celsius) |
| Storage and Shipping Conditions Relative Humidity | 10% - 100% |
| Control Unit Agency Approvals | UL Classified Medical Equipment UL 60601-1 Can/CSA C22.2 No. 601.1 |